2026 Sewer Cleaning and Televising

Project No:  12-522-79

Location:  McKees Rocks, Allegheny County, PA

Owner:  Borough of McKees Rocks

Manager:  Doug Evans

Estimated Cost:  $125,000

 

 

ContractorContact PersonBid Amount
Borough of McKees Rocks
340 Bell Avenue
McKees Rocks, PA  15136
LeeAnn WozniakN/A
Roto-Rooter Services
3731 William Penn Highway US22
Murrysville, PA  15668
Diane Freliche
Robinson Pipe Cleaning Company
2656 Idlewood Road
Pittsburgh, PA  15205
Jake Butter

 

Bid Advertisement

Sealed Bids are requested by the Borough of McKees Rocks at 340 Bell Avenue, McKees Rocks, PA 15136 until 3:00 P.M. prevailing time, Thursday, June 4, 2026 for the 2026 Sewer Cleaning and Televising Project.  Bids will be opened publicly and read aloud immediately after the closing time for receipt of Bids.

Interested parties may view the Profile and Bid Schedule for this Project on the internet at:  www.niraengineers.com.

All Bid Documents are available via email request to bids@niraengineers.com.  Electronic bid documents are available for a $25.00 fee and printed bid documents are available for a $80.00 fee with an additional charge of $15.00 when shipping is requested.  Checks are to be made payable to NIRA Consulting Engineers, Inc.  Each Bid must be accompanied by a Bid Bond, in the form of a Certified Check or Corporate Surety Bid Bond, in the amount of ten percent (10%) of the Bid Proposal made in the favor of the Borough of McKees Rocks.  Only bids from Contractors who have obtained documents directly from NIRA Consulting Engineers, Inc. will be accepted at bid opening.

A Performance Bond and a Labor and Material Payment Bond in the amounts specified within the Contract Documents will be required of the successful Bidder.

Bidders on this work will be required to comply with the Provisions of the Public Works Employment Verification Act (PWEVA).

Adherence to Instructions to Bidders is required.

No Bid or any part thereof shall be withdrawn by Bidder for a period of sixty (60) days subsequent to the Bid Opening.

The right is reserved by the Owner to reject any or all Bids or parts of bids and to waive technical defects in any Bid.

Project Scope

The work generally consists of all labor, equipment, and supervision required to perform cleaning and closed circuit televising of approximately 11,700 LF of 8 inch to 60 inch diameter combined sanitary sewer pipe, as shown on the accompanying maps.  Work shall also include special cleaning areas, catch basin cleaning, and miscellaneous associated work items.  Contractor shall be responsible for providing source of water.  Work shall also include proper disposal of debris and submission of inspection documents.

Bid Schedule

Item No.DescriptionEstimated
Quantity
Unit
1.Mobilization, Insurance, and Bonds.JOBLS
2.8 Inch Diameter
a.      Light Cleaning and Televising.291LF
b.      Heavy Cleaning and Televising.0LF
c.      Extra Heavy Cleaning and Televising.0LF
3.10 Inch Diameter
a.      Light Cleaning and Televising.359LF
b.      Heavy Cleaning and Televising.154LF
c.      Extra Heavy Cleaning and Televising.0LF
4.12 Inch Diameter
a.      Light Cleaning and Televising.3,635LF
b.      Heavy Cleaning and Televising.1,039LF
c.      Extra Heavy Cleaning and Televising.519LF
5.15 Inch Diameter
a.      Light Cleaning and Televising.1,426LF
b.      Heavy Cleaning and Televising.407LF
c.      Extra Heavy Cleaning and Televising.204LF
6.18 Inch Diameter
a.      Light Cleaning and Televising.19LF
b.      Heavy Cleaning and Televising.0LF
c.      Extra Heavy Cleaning and Televising.0LF
7.36 Inch Diameter
a.      Light Cleaning and Televising.170LF
b.      Heavy Cleaning and Televising.0LF
c.      Extra Heavy Cleaning and Televising.0LF
8.48 Inch Diameter
a.      Light Cleaning and Televising.994LF
b.      Heavy Cleaning and Televising.426LF
c.      Extra Heavy Cleaning and Televising.0LF
9.60 Inch Diameter
a.      Light Cleaning and Televising.1,449LF
b.      Heavy Cleaning and Televising.621LF
c.      Extra Heavy Cleaning and Televising.0LF
10.Special Cleaning Area
a.      8 Inch Diameter217LF
b.      12 Inch Diameter227LF
c.      15 Inch Diameter1,051LF
d.      18/20 Inch Diameter558LF
e.      24 Inch Diameter1,922LF
f.       30 Inch Diameter236LF
g.      36 Inch Diameter1,029LF
11.Special Cleaning Area – Thompson Ave.4Hrs.
12.Flow Management for 60 Inch Pipe (As Needed).2,070LF
13.Manhole Heavy Cleaning (As Directed).5EA
14.Catch Basin Cleaning (As Directed).71EA
15.Storm Pipe Cleaning (As Directed).300LF
16.Root Cutting (As Directed).5EA
17.Cut Back Protruding Lateral (As Directed).5EA
18.Locate and Mark Manhole (As Directed).5EA
19.Provision of Reports and DVD’s.JOBLS
NOTES:1.      Light Cleaning, Heavy Cleaning, and Extra Heavy Cleaning Costs are Independent of Each Other.  DO NOT Do an Add-On Type Cost. 
 2.      For Items with a Zero (0) Quantity, Provide a Unit Cost in the Event That it is Field Determined to be Required.  All Units and Cleaning Types are Estimated Based on Known Information. However, Different Levels of Cleaning May be Determined to be Required. 
NIRA Consulting Engineers, Inc.

950 Fifth Avenue, Coraopolis, PA 15108
412.262.3970